Home backup power calculator: will it run my house's essentials, and for how long?

As an Amazon Associate I earn from qualifying purchases.

The verdict

Porchlight's data on 20 exact US backup power models: only 6 can run a 240 V load from one box, and measured idle draw runs from about 10 W to 58 W. The tool checks every box against your own loads and crowns none of them.

Porchlight's backup power data covers 20 exact US models, 15 power stations and 5 generators, and its sharpest finding is this: only 6 of the 20 can feed a deep-well pump or a whole-house air conditioner that needs 240 V, and they do it from one box. Two more manage it only if you buy a second unit. The next surprise is the tax a power station pays just for being switched on. Leading measured idle draw runs from about 10 W at the frugal end to 58 W on the Jackery Explorer 5000 Plus, and at the top of that range the box spends more in a day doing nothing than a modern fridge uses. Every cell in the table carries its source, what kind of evidence it is and the date we checked it. Where nobody has measured something, the cell says so.

Will it run my house's essentials through an outage, and for how long?

Fuel allowed?

Generators run outdoors, 20 ft from the house, per CPSC (opens in a new tab).

Loads

Refrigerator

1.3 kWh a day, about 110–130 W with the compressor on (The Solar Lab, three household fridges measured over 24 h (opens in a new tab)). Starting allowance 2,200 W (Westinghouse WGen9500DFc manual’s table (opens in a new tab), refrigerator or freezer 700 W running / 2,200 W starting).

CPAP (humidifier off)

About 30 W while in use, 8 hours a night by default (tester’s estimate from a ResMed AirSense 10 measured at 22–35 W (opens in a new tab)). Heated humidification raises it.

Gas furnace blower

About 180–500 W measured whole-furnace draw in owner tests; no sourced duty cycle exists, so enter the hours a day. Starting allowance 2,350 W (same Westinghouse table (opens in a new tab): furnace 1/2 hp, 800 W running / 2,350 W starting).

Sump pump (1/3 hp)

800 W running / 1,300 W starting (same Westinghouse table (opens in a new tab)). Enter the minutes a day it runs.

Well pump, 240 V

The start check uses Franklin Electric’s minimum generator rating (opens in a new tab) for 3-wire motors (internally regulated: 1/2 hp 1.5 kW, 3/4 hp 2 kW, 1 hp 2.5 kW, 1.5 hp 3 kW; 50% higher for 2-wire motors), flagged as a 2007 edition. Running watts: 1,000 W for 1/3 hp from the Westinghouse table; above that, enter yours.

Central AC or heat pump

No watts preset. A soft start decides most cases (one cut a 2-ton AC’s inrush “by more than 65%” (opens in a new tab)); Whole house battery backup without solar covers it.

Anything else

Type the watts and hours. No preset for routers, Starlink or lights: no kept measurement.

11 h is the 2024 US average (EIA (opens in a new tab)); South Carolina’s 2024 average was nearly 53 h.

Stored in an unheated garage?

    Maker surge figures last a fraction of a second, and the Apex 300’s manual limits its surge to resistive loads (the cell note says so).

    Close-upHomePower 3600 Plus, close-up
    HomePower 3600 PlusAmazon listing

    Results are ordered by which boxes pass your checks, then by whether they cover your outage, then by hours. Never by price, score or anyone’s ranking.

    What the data shows

    Will it run my 240 V well pump or central AC?

    Usually not. Twelve of the 20 put out 120 V and nothing else. The six that give 240 V from one box are the BLUETTI Apex 300, the Jackery Explorer 5000 Plus, the Anker SOLIX F3800 Plus, the Anker SOLIX S5000, the Champion 201175 and the Westinghouse WGen9500DFc. The Anker SOLIX F3000 and the Jackery HomePower 3600 Plus need a second unit paired with the first. Shop on battery size alone and you can carry home a handsome 3,584 Wh box that cannot turn a 240 V pump over at all.

    Having 240 V is not the same as starting a motor. Makers' surge figures are brief: Anker says the S5000's peak lasts "a fraction of a second", and BLUETTI's own manual limits the Apex 300's headline surge to resistive loads like heaters, while its sales page pitches the same figure at "devices with high startup power demands". Only one maker here publishes a motor-start rating at all: Anker gives the F3800 Plus an 80 A locked-rotor limit. So the calculator checks a pump's start against Franklin Electric's minimum generator size for that horsepower, half as much again for a two-wire pump, and labels the answer "on paper", because Franklin wrote that table for engine generators, not batteries.

    How long will a power station really last in an outage?

    Shorter than the box implies, and the culprit is idle draw. An inverter that is on all day burns energy whether the fridge compressor is running or not, and during an outage it is on all day. On the calculator's own fridge-only check, the Explorer 5000 Plus has more than twice the measured usable energy of BLUETTI's smaller Elite station and lasts only about a third longer. It is a pickup with twice the tank that idles in the driveway all night.

    The runtime sum is plain: measured usable energy, divided by your loads plus the box's own idle draw over 24 hours. It is our arithmetic from the figures in the row, and it says so on screen. Where no lab has measured usable energy, the tool falls back on the maker's rated capacity and labels it as such.

    Will my gas furnace light on it?

    Watts are rarely the problem. Before it lights the burners, a furnace's control board looks for a link between the neutral wire and ground, and Goodman's spec sheet names a polarity-or-grounding fault as one of the codes its board flashes when that link is missing. Whether the link exists depends on two things: how the box is built, and how you connect it.

    • A floating box plugged straight into the furnace needs a bonding plug. Anker's C2000 Gen 2 manual says as much. Some stations' outlets have no ground contact, so the plug has to ride on a splitter instead.
    • A floating box fed through an inlet and interlock, or a transfer switch that doesn't switch the neutral, borrows its bond from your house panel. Don't add a bonding plug on top; Trystar and electrician Mike Holt both explain why a second bond makes a parallel path.
    • A bonded generator (the Champion 201175, the Generac iQ5200 DF and the WGen9500DFc say so in their paperwork) should light a furnace plugged straight in, but through an interlock it needs a transfer switch that switches the neutral.

    Here is the uncomfortable part. For 9 of the 20 models, nobody has published which kind they are, and 3 of the 11 known answers come from a sibling's paperwork. A homemade cord with male plugs at both ends, pushed into a dryer outlet, can send power back down the street to a lineworker who thinks the wire is dead; don't build one. Check your setup with your local inspector before the storm, not during it.

    How to read a row

    Each value wears a small tag: measured (a lab or reviewer), claimed (the maker) or observed (an owner). Open the cell to see who, where and when.

    A cell marked as a sibling's figure comes from a near relative, never passed off as the real thing: the C1000 Gen 2's bond rests on the C1000X Gen 2 manual, which shares its model code; the DELTA 3 Max's bond rests on EcoFlow's DELTA 3 Classic FAQ; the Westinghouse iGen5000DFc figures come from the iGen5000DFcv manual, the same generator with a wheel kit.

    A marker reading "sources disagree" means the leading figure has company. The data holds 31 conflicting figures, all kept beside the one in the cell. Some gaps are large. The HomePower 3600 Plus idled at 34 W for one tester and 21 W for another. The Explorer 5000 Plus switched over through its transfer switch in about 20 ms for two testers and took about 3,000 ms, three full seconds, on a launch unit. Three seconds is long enough to reboot a router and a CPAP.

    A few rows carry flags. The F3800 Plus idle figure is an owner's report from before a firmware update that, by Silver Cymbal's measurement, halved the idle loss. The DELTA 3800 Gen4 and S5000 figures come from maker-supported or pre-release units; both are too new for an independent lab.

    On generator rows, the battery columns read "n/a: runs on fuel" rather than "not measured", because a generator has no battery to measure.

    The evidence table

    Home backup power measurements

    Will it run my house's essentials through an outage, and for how long?

    Download CSV Cite this
    measured a lab or reviewerclaimed the makerobserved an ownersibling’s figuresources disagreeOpen the cell to see who, where and when.
    ProductIdle draw with the AC onWUsable energy, measuredWhRated capacityWhContinuous output (gas: running watts)WSurge (gas: starting watts)W240 V outputNeutral-ground bondUPS switchovermsCharges down to°FCPSC recallWeightlbWarrantyyears
    AnkerSOLIX C1000Power station Link
    6.2 Wmeasured

    Idle draw with the AC on (W)

    • 6.2 W measuredJasonoid (YouTube) · checked 2026-11-13AC inverter on, no load, 12 h: 100% to 93% on the screen. Watts are our arithmetic: 7% of 1,056 Wh over 12 h is about 6.2 W (the tester gives only the percentage). State-of-charge method, so +/- about 1% of the battery is within reading error. Jasonoid (US), video 2024-04-26 (older than 12 months);youtube.com (opens in a new tab)
    897 Whmeasuredsources disagree

    Usable energy, measured (Wh)

    • 897 Wh measuredOutdoorGearLab (Kenji Mowrey) · checked 2026-11-13AC output, 85% of rated; at max output it ran 33 min; review dated 2025-05-18 (older than 12 months)outdoorgearlab.com (opens in a new tab)

    Sources disagree

    • 650 Wh measuredOutdoor Life (Laura Lancaster) · checked 2026-11-13~34W grow light on AC for 17.3 h: 62% of rated; inverter overhead dominates at low loads (May 2025, older than 12 months)outdoorlife.com (opens in a new tab)
    • 950 Wh measuredOutdoor Life (Laura Lancaster) · checked 2026-11-13~380W dehumidifier, 2.6 h: 90% of ratedoutdoorlife.com (opens in a new tab)
    • 930 Wh measuredFootprint Hero (Alex Beale, YouTube) · checked 2026-11-135,100 BTU window AC at about 400 W, 2 h 17 min; smart plug read 0.93 kWh (88% of rated). Footprint Hero (Alex Beale): unit named as the Anker SOLIX C1000 in the video description (kept as https://www.youtube.com/watch?v=dTIIvMqBs48#description); video 2024-08-23, older than 12 months; same unit as his 2023 test, for which Anker sent a solar panel; affiliate links in the description; smart plug / Kill A Watt on the AC sideyoutube.com (opens in a new tab)
    • 800 Wh measuredFootprint Hero (Alex Beale, YouTube) · checked 2026-11-13TV at about 75-96 W, just under 10 h; smart plug read 0.8 kWh (about 80%). Footprint Hero (Alex Beale): unit named as the Anker SOLIX C1000 in the video description (kept as https://www.youtube.com/watch?v=dTIIvMqBs48#description); video 2024-08-23, older than 12 months; same unit as his 2023 test, for which Anker sent a solar panel; affiliate links in the description; smart plug / Kill A Watt on the AC sideyoutube.com (opens in a new tab)
    • 636 Wh measuredFootprint Hero (Alex Beale, YouTube) · checked 2026-11-13laptop + monitor at about 30 W, 21 h 15 min; 420 + 216 Wh on the smart plug (about 60%). Footprint Hero (Alex Beale): unit named as the Anker SOLIX C1000 in the video description (kept as https://www.youtube.com/watch?v=dTIIvMqBs48#description); video 2024-08-23, older than 12 months; same unit as his 2023 test, for which Anker sent a solar panel; affiliate links in the description; smart plug / Kill A Watt on the AC sideyoutube.com (opens in a new tab)
    • 910 Wh measuredJasonoid (YouTube) · checked 2026-11-13AC inverter drained until shutdown, 86.1% of rated; load not stated in the transcript. DC output gave 946 Wh (89.5%). Jasonoid (US), video 2024-04-26 (older than 12 months);youtube.com (opens in a new tab)
    • 970 Wh measuredThe Solar Pit (YouTube) · checked 2026-11-1392.7% of 1,056 Wh, as he reports it; load and method not stated in the video. Unit is the expandable 1,056 Wh model. Video 2025-09-15.youtube.com (opens in a new tab)
    1,056 Whclaimed

    Rated capacity (Wh)

    1,800 Wclaimed

    Continuous output (gas: running watts) (W)

    not measurednot measurednot stated by the maker
    16.1 msmeasuredsources disagree

    UPS switchover (ms)

    • 16.1 ms measuredJasonoid (YouTube) · checked 2026-11-13Oscilloscope on the AC output while a stress-tested desktop PC, monitor and studio lights ran in UPS mode; the PC and monitor stayed on through three cuts. Jasonoid (US), video 2024-04-26 (older than 12 months);youtube.com (opens in a new tab)

    Sources disagree

    32 °Fclaimed

    Charges down to (°F)

    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13no recall naming A1761 or an Anker power station; Anker recalls are power banks, speakers and EverFrost coolerscpsc.gov (opens in a new tab)
    28.44 lbclaimed

    Weight (lb)

    5 yearsclaimed

    Warranty (years)

    AnkerSOLIX C1000 Gen 2Power station Link
    14 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    Sources disagree

    • 13.6 W measuredMinute Man Solar (YouTube) · checked 2026-11-13AC inverter on, nothing plugged in; 13.6 to 15 Wh per hour over several runs; video 2025-08-30 (launch review; whether Anker supplied the unit is not stated)youtube.com (opens in a new tab)
    • 9 W claimedAnker, as listed by The Gadgeteer · checked 2026-11-13'standby power consumption is just 9W, 37.5% lower than the industry average' in the review's copy of Anker's feature list; load condition not stated; not seen on Anker's US product page kept in this runthe-gadgeteer.com (opens in a new tab)
    • 13.8 W measured sibling’s figureThe Solar Lab · checked 2026-11-13C1000X Gen 2, AC inverter on with no loadyoutube.com (opens in a new tab)
    870.08 Whmeasuredsources disagree

    Usable energy, measured (Wh)

    • 870.08 Wh measuredCNET Labs · checked 2026-11-13discharge into a 480 W load logged at 1-min intervals until depletion; 85.0% of rated; article updated Aug 13 2026; US site, unit market not statedcnet.com (opens in a new tab)

    Sources disagree

    • 875 Wh measuredJungle River (YouTube) · checked 2026-11-131,000 W constant load through a kWh meter, 85% of rated; video 2025-11-27youtube.com (opens in a new tab)
    1,024 Whclaimed

    Rated capacity (Wh)

    2,000 Wclaimed

    Continuous output (gas: running watts) (W)

    • 2,000 W claimedAnker · checked 2026-11-133,000 W peak on the US page; the Anker troubleshooting guide says SurgePad runs heating devices up to 2,400 W and is not recommended for motor-driven devices like refrigerators or air conditionersankersolix.com (opens in a new tab)
    3,000 Wclaimed

    Surge (gas: starting watts) (W)

    120V onlyclaimed

    240 V output

    floatingclaimedsibling’s figure

    Neutral-ground bond

    • floating claimed sibling’s figureAnker (C1000X Gen 2 manual) · checked 2026-11-13Mode: inverter output. Manual for the C1000X Gen 2, which carries the same model code A1763 and FCC filing, FAQ 9: 'The power station uses a floating ground design, so you'll need to purchase a ground neutral plug'. The C1000 Gen 2's own English user guide was not obtained: Anker's service page (service.ankersolix.com) did not render in Chrome, device.report is behind a bot wall, the Amazon PDF (kept) is a troubleshooting guide without grounding text, and the manuals.plus copies carry no grounding text. Anker's C2000 Gen 2 manual (kept) uses the same wording. No measured check found.pdf.lowes.com (opens in a new tab)
    10 msclaimed

    UPS switchover (ms)

    32 °Fclaimed

    Charges down to (°F)

    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13no recall naming A1763 or an Anker power station; Anker recalls listed are power banks, speakers and EverFrost coolerscpsc.gov (opens in a new tab)
    24.9 lbclaimed

    Weight (lb)

    not measured
    AnkerSOLIX C2000 Gen 2Power station Link
    18 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    Sources disagree

    1,812.04 Whmeasured

    Usable energy, measured (Wh)

    2,048 Whclaimed

    Rated capacity (Wh)

    2,400 Wclaimed

    Continuous output (gas: running watts) (W)

    4,000 Wclaimedsources disagree

    Surge (gas: starting watts) (W)

    • 4,000 W claimedAnker · checked 2026-11-13US page: 4,000W peak; the manual says SurgePad supports up to 3,000 W AC output and does not work in bypass modeankersolix.com (opens in a new tab)

    Sources disagree

    120V onlyclaimed

    240 V output

    • 120V only claimedAnker · checked 2026-11-13spec table: AC Output (NEMA 5-20R) and AC Output (TT-30R) both '120V~ 20A Max, 60Hz, 2400W Max'; no 240 V outputankersolix.com (opens in a new tab)
    floatingclaimed

    Neutral-ground bond

    • floating claimedAnker (manual) · checked 2026-11-13FAQ 8: 'uses a floating ground design'; devices needing a neutral-ground bond need a ground-neutral plugcdn.shopify.com (opens in a new tab)
    10 msclaimed

    UPS switchover (ms)

    32 °Fclaimed

    Charges down to (°F)

    none foundclaimed

    CPSC recall

    41.7 lbclaimed

    Weight (lb)

    not measured
    AnkerSOLIX F3000Power station Link
    20.5 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    Sources disagree

    • 26.6 W measuredThe Solar Lab · checked 2026-11-13After one year: two runs gave 37.2W and 16.6W; the average is shown; tester calls it inconsistentyoutube.com (opens in a new tab)
    • 35 W measuredHOBOTECH (YouTube) · checked 2026-11-13AC on, no load, 12 h, refilled through solar port and metered: ~832Wh per 24 h; 88 h to empty vs Anker's 125 h standby claim. Firmware as of 28 Aug 2025youtube.com (opens in a new tab)
    • 20 W measuredJasonoid (YouTube) · checked 2026-11-138% state of charge over 12 h with AC on (0.66%/h of 3,072Wh), screen-basedyoutube.com (opens in a new tab)
    2,645.91 Whmeasured

    Usable energy, measured (Wh)

    • 2,645.91 Wh measuredCNET Labs · checked 2026-11-13480W resistive load, HOBOware logger, run to empty; 86.1% of rated. Jul-Aug 2026cnet.com (opens in a new tab)
    3,072 Whclaimed

    Rated capacity (Wh)

    3,600 Wclaimed

    Continuous output (gas: running watts) (W)

    7,200 Wclaimed

    Surge (gas: starting watts) (W)

    120V only (240V needs two units plus Double Voltage Hub)claimed

    240 V output

    floatingmeasured

    Neutral-ground bond

    • floating measuredJasonoid (YouTube) · checked 2026-11-13Mode: battery = floating (outlets and TT-30R); AC-charging = takes ground from the charging source; EV mode = bonded (AC charging disabled). Outlets and TT-30R float on battery; pick up ground from the charging source when AC-charging; EV mode bonds neutral and ground (AC charging disabled in EV mode)youtube.com (opens in a new tab)
    9.8 msmeasuredsources disagree

    UPS switchover (ms)

    • 9.8 ms measuredJasonoid (YouTube) · checked 2026-11-13Oscilloscope on the outlet during grid cut, PC under stress test; three cuts, PC stayed on. Jul 2025youtube.com (opens in a new tab)

    Sources disagree

    32 °Fclaimed

    Charges down to (°F)

    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13CPSC listing downloaded 2026-11-13 (10,134 recalls, newest 2026-11-05) searched for Anker: every Anker recall is a power bank, speaker or EverFrost cooler battery; none names an Anker SOLIX power station or the F3000cpsc.gov (opens in a new tab)
    91.5 lbclaimed

    Weight (lb)

    5 yearsclaimed

    Warranty (years)

    AnkerSOLIX F3800 PlusPower stationidle: owner’s report from before a firmware update Link
    40 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    • 40 W measuredSilver Cymbal (YouTube) · checked 2026-11-13worked out: 25% of the rated 3840 Wh lost in 24 h. Same test after Anker's firmware update (about 40W); outlet checked live with a voltmeter and a heateryoutube.com (opens in a new tab)

    Sources disagree

    • 80 W measuredSilver Cymbal (YouTube) · checked 2026-11-13worked out: 50% of the rated 3840 Wh lost in 24 h. AC inverter on, no load, 24 h, launch firmware (about 80W)youtube.com (opens in a new tab)
    • 50-70 (reported, pre-update) observedBertel King, owner (Yahoo Tech / How-To Geek) · checked 2026-11-13Owner of about a year, three outages each restored within the day; quotes reported 50-70W before the update; app estimate went from just over 2 days to about 4 days after updatingtech.yahoo.com (opens in a new tab)
    3,235 Whmeasured

    Usable energy, measured (Wh)

    • 3,235 Wh measuredSilver Cymbal (YouTube) · checked 2026-11-13Run to zero under load after the idle-fix firmware; 85% of rated. Apr 2025youtube.com (opens in a new tab)
    3,840 Whclaimed

    Rated capacity (Wh)

    6,000 Wclaimed

    Continuous output (gas: running watts) (W)

    not measured
    120V/240V split-phase from one unit (NEMA L14-30R, 25A)claimed

    240 V output

    not stated by the maker
    20 msclaimed

    UPS switchover (ms)

    • 20 ms claimedAnker · checked 2026-11-13FAQ Condition 4: only the three leftmost 5-20R outlets are UPS; TT-30R has no UPS; bypass limit 1,440Wankersolix.com (opens in a new tab)
    not measured
    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13CPSC listing downloaded 2026-11-13 (10,134 recalls, newest 2026-11-05) searched for Anker: every Anker recall is a power bank, speaker or EverFrost cooler battery; none names an Anker SOLIX power station or the F3800 Pluscpsc.gov (opens in a new tab)
    136.7 lbclaimed

    Weight (lb)

    5 yearsclaimed

    Warranty (years)

    AnkerSOLIX S5000Power stationmaker-supported or pre-release units Link
    10 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    • 10 W measuredpv magazine USA (Andrew Riha) · checked 2026-11-13Lost 5% SoC in 24 h on battery, 120V output on, nothing connected; display shows whole percent. Pre-release unit, Oct 2026now.solar (opens in a new tab)

    Sources disagree

    4,870 Whmeasured

    Usable energy, measured (Wh)

    • 4,870 Wh measuredpv magazine USA (Andrew Riha) · checked 2026-11-13App-reported discharge, output not metered; 97% of nameplate. Pre-release unitnow.solar (opens in a new tab)
    5,024 Whclaimed

    Rated capacity (Wh)

    4,500 Wclaimed

    Continuous output (gas: running watts) (W)

    8,000 Wclaimed

    Surge (gas: starting watts) (W)

    120V/240V from one unit (L14-30R 4,500W, TT-30R 3,600W, 5-20R 2,400W)claimed

    240 V output

    not stated by the maker
    10 msclaimed

    UPS switchover (ms)

    not measured
    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13CPSC listing downloaded 2026-11-13 (10,134 recalls, newest 2026-11-05) searched for Anker: every Anker recall is a power bank, speaker or EverFrost cooler battery;cpsc.gov (opens in a new tab)
    97 lbclaimed

    Weight (lb)

    5 yearsclaimed

    Warranty (years)

    BLUETTIAC180Power station Link
    13.8 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    • 13.8 W measuredJasonoid (YouTube) · checked 2026-11-13AC inverter enabled, no load, 10 h: 100% to 88% on the screen ('about 1.2% per hour'). Watts are our arithmetic: 12% of 1,152 Wh over 10 h is about 13.8 W. State-of-charge method. Video 2023-06-14 (older than 12 months). Agrees with BLUETTI's 'about 15W' and the 14 W it gave Outdoor Life.youtube.com (opens in a new tab)

    Sources disagree

    950 Whmeasuredsources disagree

    Usable energy, measured (Wh)

    • 950 Wh measuredOutdoorGearLab (Kenji Mowrey) · checked 2026-11-13light-bar jig at 80% load (about 1,440W) until empty; 82% of rated; review dated 2026-01-13outdoorgearlab.com (opens in a new tab)

    Sources disagree

    • 1,030 Wh measuredStorageReview · checked 2026-11-13350W load, inverter losses included; review dated 2023-05-26 (older than 12 months)storagereview.com (opens in a new tab)
    • 620 Wh measuredOutdoor Life (Laura Lancaster) · checked 2026-11-13~34W grow light on AC for 15.1 h: 54% of rated; low loads lose most to inverter overhead (May 2025, older than 12 months)outdoorlife.com (opens in a new tab)
    • 980 Wh measuredOutdoor Life (Laura Lancaster) · checked 2026-11-13~380W dehumidifier, 2.7 h: 85% of ratedoutdoorlife.com (opens in a new tab)
    • 990 Wh measuredJasonoid (YouTube) · checked 2026-11-13AC inverter drained to 0%, 85.9% of rated; the auto-captions give the load as a '2C rate', which is unclear. Video 2023-06-14 (older than 12 months).youtube.com (opens in a new tab)
    • 1,030 Wh measuredHOBOTECH (YouTube) · checked 2026-11-13AC battery capacity test, 89% of rated; DC test gave a near-identical result (auto-captions '1,39' Wh, 90%). Load not stated. Video 2023-06-14 (older than 12 months).youtube.com (opens in a new tab)
    • 1,044 Wh measuredReeWray Outdoors (YouTube) · checked 2026-11-13200 W space heater on the AC inverter from 100% until shutdown, watt meter; 91% of rated. 55 dB near the 1,800 W maximum. A battery-less laptop stayed on when the wall feed was pulled (UPS confirmed). Video 2023-09-25 (older than 12 months).youtube.com (opens in a new tab)
    1,152 Whclaimed

    Rated capacity (Wh)

    1,800 Wclaimed

    Continuous output (gas: running watts) (W)

    not measurednot measurednot stated by the maker
    8.7 msmeasuredsources disagree

    UPS switchover (ms)

    • 8.7 ms measuredJasonoid (YouTube) · checked 2026-11-13Oscilloscope on the AC output in his C1000 vs AC180 vs DELTA 2 head-to-head; fastest of the three (C1000 19.2 ms, DELTA 2 19.8 ms). Video 2024-07-05 (older than 12 months). Single timed measurement reported.youtube.com (opens in a new tab)

    Sources disagree

    not measured
    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13no recall naming BLUETTI or AC180 in the full CPSC listing downloaded 2026-11-13cpsc.gov (opens in a new tab)
    37 lbclaimed

    Weight (lb)

    5 yearsclaimed

    Warranty (years)

    BLUETTIApex 300Power station Link
    20 Wmeasuredsources disagree2 labs agree

    Idle draw with the AC on (W)

    Sources disagree

    • 16 W measuredThere's A Trick For That (YouTube) · checked 2026-11-137% SoC over 12 h, inverter on, no load; reviewer computes 387 Wh/24 h. Oct 2025youtube.com (opens in a new tab)
    • 19.5 W measured sibling’s figureESS News · checked 2026-11-13hands-on at IFA 2025 (Berlin); unit market not stated; inverters oness-news.com (opens in a new tab)

    2 labs agree

    2,480 Whmeasuredsources disagree

    Usable energy, measured (Wh)

    • 2,480 Wh measuredThere's A Trick For That (YouTube) · checked 2026-11-13power meter, heavy load (reviewer says about 2C) into a charger, 89%youtube.com (opens in a new tab)

    Sources disagree

    2,764.8 Whclaimed

    Rated capacity (Wh)

    3,840 Wclaimed

    Continuous output (gas: running watts) (W)

    7,680 Wclaimed

    Surge (gas: starting watts) (W)

    • 7,680 W claimedBLUETTI · checked 2026-11-13maker page: '3,840W output and 7,680W surge power ... devices with high startup power demands'. The manual calls 7,680W 'Power Lifting' for pure resistive loads only (5.3); see Conflictsbluettipower.com (opens in a new tab)
    yesclaimed

    240 V output

    • yes claimedBLUETTI · checked 2026-11-13voltage selector set to 240V: 14-50R gives 120/240V split phase at 16A max (3,840W) on one unit; the 5-20R outlets then give 1,920W max per pair and TT-30 16A max. Switching voltage cuts AC outputs4.bluettipower.com (opens in a new tab)
    not stated by the maker
    16 msmeasuredsources disagree

    UPS switchover (ms)

    • 16 ms measuredStorageReview (2026-11-10) · checked 2026-11-13Quarch capture, 120V (20 ms) mode, at 100W idle and 700W load; the 0 ms 240V-mode path was not capturedstoragereview.com (opens in a new tab)

    Sources disagree

    • 0 ms claimedBLUETTI · checked 2026-11-130 ms only in 240V mode, on the two left AC outlets, with grid on the 15A input; 20 ms on other outlets and in 120V mode (manual 7)s4.bluettipower.com (opens in a new tab)
    32 °Fclaimed

    Charges down to (°F)

    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13CPSC listing downloaded 2026-11-13 (10,134 recalls, newest 2026-11-05) filtered for BLUETTI and 'power station': no BLUETTI recallcpsc.gov (opens in a new tab)
    83.78 lbclaimed

    Weight (lb)

    not measured
    BLUETTIElite 100 V2Power station Link
    16 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    Sources disagree

    • 10 W measuredReeWray Outdoors (YouTube) · checked 2026-11-13AC inverter on, no load, 24 h: about 1% of capacity per hour; read from the % display, so coarseyoutube.com (opens in a new tab)
    • 10 W claimedBLUETTI user manual V5.1 · checked 2026-11-13FAQ Q5: 'self-consumption is about 10W'; DoD 90%, inverter efficiency over 90% claimeds4.bluettipower.com (opens in a new tab)
    890 Whmeasuredsources disagree

    Usable energy, measured (Wh)

    • 890 Wh measuredOutdoorGearLab (Kenji Mowrey) · checked 2026-11-13light-bar load bank, AC output; 87% of rated; review dated 2026-07-23; US publication that buys its units, unit market not statedoutdoorgearlab.com (opens in a new tab)

    Sources disagree

    • 930 Wh measuredReeWray Outdoors (YouTube) · checked 2026-11-13AC discharge at just under 700W from full until BMS cut-off, watt meter at 119.6V: 91% of rated; video 2025-07-01, pre-launch unit with pricing information from BLUETTI (likely maker-supplied)youtube.com (opens in a new tab)
    • 937.25 Wh measured sibling’s figureCNET Labs · checked 2026-11-13Elite 100 V2 Bio-Based, the bio-plastic look-alike; 83.44% round-trip efficiency, best in CNET's medium class; standard-load discharge per CNET's methodcnet.com (opens in a new tab)
    1,024 Whclaimed

    Rated capacity (Wh)

    1,800 Wclaimed

    Continuous output (gas: running watts) (W)

    3,600 Wclaimed

    Surge (gas: starting watts) (W)

    • 3,600 W claimedBLUETTI (Amazon US listing title) · checked 2026-11-13'3600W Surge' in the Amazon title; the US store page gives only the 2,700W Power Lifting figureamazon.com (opens in a new tab)
    not measurednot stated by the maker
    10 msclaimed2 labs agree

    UPS switchover (ms)

    2 labs agree

    • 10 ms claimedBLUETTI user manual V5.1 · checked 2026-11-13'<=10 ms'; the manual also says not for data servers or workstations that require high-performance UPSs4.bluettipower.com (opens in a new tab)
    not measured
    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13no recall naming BLUETTI in the full CPSC listing downloaded 2026-11-13cpsc.gov (opens in a new tab)
    25 lbclaimed

    Weight (lb)

    5 yearsclaimed

    Warranty (years)

    BLUETTIElite 200 V2Power station Link
    14.7 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    • 14.7 W measuredHOBOTECH (YouTube) · checked 2026-11-1388 Wh over 6 h with inverter on and no load, measured by the energy needed to recharge via the solar port (includes charge losses); 352 Wh/24 h. Nov 2024youtube.com (opens in a new tab)

    Sources disagree

    1,987.98 Whmeasuredsources disagree

    Usable energy, measured (Wh)

    • 1,987.98 Wh measuredCNET Labs · checked 2026-11-13CNET active-energy test; 95.9% of 2,073.6Wh. Article dated Aug 2026cnet.com (opens in a new tab)

    Sources disagree

    2,073.6 Whclaimed

    Rated capacity (Wh)

    2,600 Wclaimed

    Continuous output (gas: running watts) (W)

    not measured
    noclaimed

    240 V output

    not stated by the maker
    15 msclaimed

    UPS switchover (ms)

    • 15 ms claimedBLUETTI · checked 2026-11-13US manual V2.0, section 12 Specifications ('<=15 ms'); 4 UPS modes in the app; manual says not for servers/workstations that need a high-performance UPSs4.bluettipower.com (opens in a new tab)
    32 °Fclaimed

    Charges down to (°F)

    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13CPSC listing downloaded 2026-11-13 (10,134 recalls, newest 2026-11-05) filtered for BLUETTI and 'power station': no BLUETTI recallcpsc.gov (opens in a new tab)
    53.35 lbclaimed

    Weight (lb)

    5 yearsclaimed

    Warranty (years)

    BLUETTIElite 300Power station Link
    15 Wmeasured3 labs agree

    Idle draw with the AC on (W)

    3 labs agree

    2,810 Whmeasuredsources disagree

    Usable energy, measured (Wh)

    Sources disagree

    • 2,670 Wh measuredStorageReview · checked 2026-11-13Kill-A-Watt, full to empty; recharge 0-100% took 3.49 kWh, so round trip about 76.5% (our division). Aug 2026storagereview.com (opens in a new tab)
    3,014.4 Whclaimed

    Rated capacity (Wh)

    2,400 Wclaimed

    Continuous output (gas: running watts) (W)

    not measured
    noclaimed

    240 V output

    not stated by the maker
    8 msmeasuredsources disagree

    UPS switchover (ms)

    Sources disagree

    • 10 ms claimedBLUETTI · checked 2026-11-13US manual V1.0, section 11 Specifications; manual says not for data servers or workstations that need a high-performance UPSs4.bluettipower.com (opens in a new tab)
    32 °Fclaimed

    Charges down to (°F)

    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13CPSC listing downloaded 2026-11-13 (10,134 recalls, newest 2026-11-05) filtered for BLUETTI and 'power station': no BLUETTI recallcpsc.gov (opens in a new tab)
    57.98 lbclaimed

    Weight (lb)

    not measured
    Champion Power Equipment201175Generator Link
    n/a: runs on fueln/a: runs on fueln/a: runs on fuel
    7,000 Wclaimed

    Continuous output (gas: running watts) (W)

    8,500 Wclaimed

    Surge (gas: starting watts) (W)

    120/240claimed

    240 V output

    bondedclaimed

    Neutral-ground bond

    n/a: runs on fueln/a: runs on fuel
    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13Champion generator recall in the listing: 13-026 (models 41332, 41532, Costco, 2012); none names 201175cpsc.gov (opens in a new tab)
    213.9 lbclaimed

    Weight (lb)

    3 yearsclaimed

    Warranty (years)

    DJIPower 1000 V2Power station Link
    18 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    Sources disagree

    880 Whmeasured

    Usable energy, measured (Wh)

    1,024 Whclaimed

    Rated capacity (Wh)

    • 1,024 Wh claimedDJI (Amazon US listing title) · checked 2026-11-13See our pick
    2,600 Wclaimedsources disagree

    Continuous output (gas: running watts) (W)

    • 2,600 W claimedDJI (Amazon US listing title) · checked 2026-11-13'2600W Stable Output'; The Solar Lab's spec list also gives 2,600W pure sineSee our pick

    Sources disagree

    • 2,200 W claimedOutdoorGearLab (stating the rating) · checked 2026-11-13OGL writes 'rated for 2,200 watts and a surge rating of up to 4,400 watts', which is the first Power 1000's inverter per The Solar Lab; see Conflicts in notesoutdoorgearlab.com (opens in a new tab)
    not measurednot measured
    floating on battery; bonded to ground when plugged into the wallmeasured

    Neutral-ground bond

    • floating on battery; bonded to ground when plugged into the wall measuredMinute Man Solar (YouTube) · checked 2026-11-13Auto-captions are garbled: 'this is not grounded when it's plugged into a wall outlet because there's no physical ground. But as soon as you do plug it into an outlet, it grounds the system.' Read as floating when unplugged; check the video before relying on it.youtube.com (opens in a new tab)
    10 msclaimed2 labs agree

    UPS switchover (ms)

    • 10 ms claimedDJI, as reported by The Technology Man · checked 2026-11-13DJI's manual says it is a basic UPS without 0 ms switching and not for medical devices needing 0 msyoutube.com (opens in a new tab)

    2 labs agree

    • 10 ms claimedDJI (UK support FAQ; Amazon US listing) · checked 2026-11-13'can start powering the connected devices within 0.01 seconds'; UPS is the default when AC is on and both grid and load are connected. Amazon US listing: 'seamless UPS with a 10ms [9] switch time'.dji.com (opens in a new tab)
    not measured
    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13no recall naming DJI in the full CPSC listing downloaded 2026-11-13cpsc.gov (opens in a new tab)
    31.3 lbclaimed

    Weight (lb)

    3 yearsclaimedsources disagree

    Warranty (years)

    Sources disagree

    • 5 years claimedTechRadar (DJI's terms as reported) · checked 2026-11-13'DJI offers up to five years of warranty coverage'; DJI's global store terms (not kept: DJI pages redirect to DJI Thailand from this reader) are reported as 3 years plus 2 after first DJI Home app connectiontechradar.com (opens in a new tab)
    • 5 years claimedDJI After-Sales Service Policies (warranty period table) · checked 2026-11-1360 Months', no app condition in the table; AC cable, MPPT module and SDC cables 12 months. Page reached from DJI's US site. The policy covers only products bought from DJI authorized retailers.dji.com (opens in a new tab)
    • 5 years claimedAmazon US listing B0H2MFBDZL (DJI brand content) · checked 2026-11-13'Backed by up to 5 years of warranty' and 'comes with a 5-year warranty [17]'; footnote 17 not visible. Who honours it for a third-party Amazon sale is not stated.See our pick
    • 5 years claimed sibling’s figureDJI UK support FAQ · checked 2026-11-13UK page: 'The default warranty period is five years. Certain accessories are not included in the 5-year warranty coverage.' UK region, not the US.dji.com (opens in a new tab)
    • 3, plus 2 after first DJI Home app connection claimed sibling’s figureDJI product FAQ and footnote as carried by Ferntech (NZ DJI dealer) · checked 2026-11-13FAQ copy: 'The default warranty period is three years. You can get an additional two-year warranty period by downloading the DJI Home app, and completing the first connection.' Footnote: units 'purchased from the DJI Store will have a three-year warranty, which can be extended by an additional two years'. NZ region.ferntech.co.nz (opens in a new tab)
    EcoFlowDELTA 3 ClassicPower station Link
    17 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    • 17 W measuredThe Solar Lab · checked 2026-11-13Inverter on, no load; ~2.5 days to empty. Same figure in The Solar Lab's written review (https://www.thesolarlab.com/review/ecoflow-delta-3-classic, 2026-07-22: 'roughly 17W per hour'); method (meter or state of charge) not stated. Field renamed from idle_draw_w on 2026-11-13 to match the other under-its price units.youtube.com (opens in a new tab)

    Sources disagree

    • 13 W measuredThe Solar Pit (YouTube) · checked 2026-11-13AC outlets on, nothing connected, screen set to always on, exactly 24 h: used 'roughly 30%', which he converts to 307 Wh and 'an estimated 13 watts'. State-of-charge method (screen %), not a meter. Video 2026-03-01.youtube.com (opens in a new tab)
    • 13 W measuredThe Solar Pit (YouTube) · checked 2026-11-13worked out: 30% of the rated 1024 Wh lost in 24 h. Same 24 h idle test, AC on, screen always on.youtube.com (opens in a new tab)
    947.47 Whmeasuredsources disagree

    Usable energy, measured (Wh)

    • 947.47 Wh measuredCNET Labs · checked 2026-11-13480W standard load via HOBOware logger, 92.5% of rated; RTE 81.34%; charge 55 min. Variant settled 2026-11-13 as the Classic: CNET names the Classic, its product image is the Classic (three AC outlets with a two-prong one in the middle, round display; Only CNET's port line ('13 total: 6 AC ...') does not fit; CNET's port lines are garbled elsewhere (it gives the Plus '3 AC outlets'), so that line is treated as a spec-box error. Independent Classic results agree: The Solar Pit 940 Wh (91.7%), my-best (JP unit) 950 Wh (92.77%).cnet.com (opens in a new tab)

    Sources disagree

    • 940 Wh measuredThe Solar Pit (YouTube) · checked 2026-11-13AC discharge, 91.7% of 1,024 Wh; the load for this figure is not stated (his continuous-discharge test ran 100% to 0% at close to 1,800 W, but he does not say the 940 Wh came from that run). Video 2026-03-01; whether EcoFlow supplied the unit is not stated. Transcript read in Chrome.youtube.com (opens in a new tab)
    1,024 Whclaimed

    Rated capacity (Wh)

    1,800 Wclaimed

    Continuous output (gas: running watts) (W)

    3,600 Wclaimed

    Surge (gas: starting watts) (W)

    120V onlyclaimed

    240 V output

    floatingclaimed

    Neutral-ground bond

    • floating claimedEcoFlow US support FAQ · checked 2026-11-13Mode: on battery (inverter output). FAQ: 'The portable power station is a floating-ground system'. The same FAQ's 'Is the device grounded? Yes ... If the device's AC input is connected to the grid, it will share the same ground as the grid power' describes the earth pin's continuity to the chassis and to grid earth while plugged in, not a neutral-ground bond, so the two answers do not contradict (conflict explained in notes). Bypass/UPS mode bonding not stated by EcoFlow; not measured on this variant.ecoflow.com (opens in a new tab)
    <10 msclaimed

    UPS switchover (ms)

    32 °Fclaimed

    Charges down to (°F)

    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall database · checked 2026-11-13CPSC API search for EcoFlow returns one recall, 26-010 (DELTA Max 2000 EFD310, Oct 2025, firmware repair after six fires); none for this modelsaferproducts.gov (opens in a new tab)
    26.7 lbclaimed

    Weight (lb)

    5 yearsclaimed

    Warranty (years)

    EcoFlowDELTA 3 MaxPower station Link
    27 Wmeasured

    Idle draw with the AC on (W)

    not measured
    2,048 Whclaimed

    Rated capacity (Wh)

    2,400 Wclaimed

    Continuous output (gas: running watts) (W)

    4,800 Wclaimed

    Surge (gas: starting watts) (W)

    120V onlyclaimed

    240 V output

    floatingclaimedsibling’s figure

    Neutral-ground bond

    • floating claimed sibling’s figureEcoFlow US support FAQ for the DELTA 3 Classic · checked 2026-11-13SIBLING statement, not the DELTA 3 Max: EcoFlow's Classic FAQ calls its stations 'a floating-ground system' on inverter output. The DELTA 3 Max US manual (kept) has only the cord-grounding instruction and says nothing on neutral bonding; the Max's own US support FAQ could not be loaded (ecoflow.com redirected to the home page in Chrome; fetch returned 3 characters). No measurement found.ecoflow.com (opens in a new tab)
    <10 msclaimed

    UPS switchover (ms)

    32 °Fclaimed

    Charges down to (°F)

    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall database · checked 2026-11-13CPSC API search for EcoFlow returns one recall, 26-010 (DELTA Max 2000 EFD310, Oct 2025, firmware repair after six fires); none for this modelsaferproducts.gov (opens in a new tab)
    44.8 lbclaimed

    Weight (lb)

    5 yearsclaimed

    Warranty (years)

    EcoFlowDELTA 3800 Gen4Power stationmaker-supported or pre-release units Link
    11 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    • 11 W measuredHOBOTECH · checked 2026-11-1324 h, inverter on, nothing plugged in, 7% of battery used; Fridge Runtime Boost mode enabled; whole-percent display so up to 12.5Wyoutube.com (opens in a new tab)

    Sources disagree

    3,330 Whmeasured

    Usable energy, measured (Wh)

    3,763 Whclaimed

    Rated capacity (Wh)

    3,600 Wclaimed

    Continuous output (gas: running watts) (W)

    7,200 Wclaimed

    Surge (gas: starting watts) (W)

    120V onlyclaimed

    240 V output

    not stated by the maker
    <10 msclaimed

    UPS switchover (ms)

    32 °Fclaimed

    Charges down to (°F)

    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall database · checked 2026-11-13CPSC API search for EcoFlow returns one recall, 26-010 (DELTA Max 2000 EFD310, Oct 2025, firmware repair after six fires); none for this modelsaferproducts.gov (opens in a new tab)
    67.46 lbclaimed

    Weight (lb)

    5 yearsclaimed

    Warranty (years)

    GeneraciQ5200 DFGenerator Link
    n/a: runs on fueln/a: runs on fueln/a: runs on fuel
    3,900 Wclaimed

    Continuous output (gas: running watts) (W)

    5,200 Wclaimed

    Surge (gas: starting watts) (W)

    120V onlyclaimed

    240 V output

    bondedclaimed

    Neutral-ground bond

    n/a: runs on fueln/a: runs on fuel
    none for iQ5200 (G0089450 not in the April 2026 GP-series carburetor recall 26-407)claimed

    CPSC recall

    • none for iQ5200 (G0089450 not in the April 2026 GP-series carburetor recall 26-407) claimedCPSC · checked 2026-11-13Recall 26-407 covers GP3600 to GP9500ETF models onlycpsc.gov (opens in a new tab)
    111 lbclaimed

    Weight (lb)

    3 yearsclaimed

    Warranty (years)

    HondaEU2200iGenerator Link
    n/a: runs on fueln/a: runs on fueln/a: runs on fuel
    1,800 Wclaimed

    Continuous output (gas: running watts) (W)

    2,200 Wclaimed

    Surge (gas: starting watts) (W)

    120V onlyclaimed

    240 V output

    floatingclaimed

    Neutral-ground bond

    • floating claimedHonda EU2200i owner's manual · checked 2026-11-13Generator, one mode. Manual: 'The generator (stator winding) is isolated from the frame and from the AC receptacle ground pin' and 'The system ground is not connected to the AC neutral wire.' Confirmed 2026-11-13.cdn.powerequipment.honda.com (opens in a new tab)
    n/a: runs on fueln/a: runs on fuel
    Recall 20-090 (Mar 2020): inverter short circuit with salt water, fire; EAMT-1000001 to 2098790; repair. Follows 2019 recall of ~200,000 for fuel-valve leakclaimed

    CPSC recall

    • Recall 20-090 (Mar 2020): inverter short circuit with salt water, fire; EAMT-1000001 to 2098790; repair. Follows 2019 recall of ~200,000 for fuel-valve leak claimedCPSC · checked 2026-11-13Units sold Feb 2018 to Jan 2020; current CO-MINDER units are later serialscpsc.gov (opens in a new tab)
    47.4 lbclaimed

    Weight (lb)

    3 yearsclaimed

    Warranty (years)

    JackeryExplorer 1000 v2Power station Link
    18 Wclaimed

    Idle draw with the AC on (W)

    not measured
    1,070 Whclaimedsources disagree

    Rated capacity (Wh)

    • 1,070 Wh claimedJackery FAQ (Oct 2026) and US tech specs · checked 2026-11-1330.4Ah/35.2V; the US page headline says 1024Wh (see conflict)jackery.com (opens in a new tab)

    Sources disagree

    • 1,024 Wh claimedJackery US page headline · checked 2026-11-13headline figure; the same page lists a 1024Wh 20Ah/51.2V 230V spec block that matches the EU JE-1000F manualjackery.com (opens in a new tab)
    1,500 Wclaimed

    Continuous output (gas: running watts) (W)

    3,000 Wclaimed

    Surge (gas: starting watts) (W)

    noclaimed

    240 V output

    not stated by the maker
    20 msclaimed

    UPS switchover (ms)

    32 °Fclaimed

    Charges down to (°F)

    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall API · checked 2026-11-13CPSC API searched by RecallTitle, Manufacturer and RecallDescription = Jackery: all empty on 2026-11-13saferproducts.gov (opens in a new tab)
    23.8 lbclaimed

    Weight (lb)

    5 yearsclaimed

    Warranty (years)

    JackeryExplorer 5000 PlusPower station Link
    58 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    Sources disagree

    4,374 Whmeasured

    Usable energy, measured (Wh)

    5,040 Whclaimed

    Rated capacity (Wh)

    7,200 Wclaimed

    Continuous output (gas: running watts) (W)

    • 7,200 W claimedJackery manual · checked 2026-11-13120V/240V split phase from NEMA L14-30R and 14-50 (30A); 4x NEMA 5-20 120V 2400W eachr.jackery.net (opens in a new tab)
    14,400 Wclaimed

    Surge (gas: starting watts) (W)

    yes, single unitclaimed

    240 V output

    floating (no ground-neutral bond)measured

    Neutral-ground bond

    • floating (no ground-neutral bond) measuredReeWray Outdoors · checked 2026-11-13EV charger refused to charge until a ground-neutral bonding plug was used; Will Prowse saw the same with a Tesla mobile connectoryoutube.com (opens in a new tab)
    20 msmeasuredsources disagree3 labs agree

    UPS switchover (ms)

    • 20 ms measuredThe Solar Lab (Smart Transfer Switch article) · checked 2026-11-13whole switchover through the Jackery Smart Transfer Switch about 20 ms; lights barely flickeredthesolarlab.com (opens in a new tab)

    Sources disagree

    • 3,000 ms measuredWill Prowse (YouTube, Nov 2024, launch unit) · checked 2026-11-13through the Smart Transfer Switch, about 3 s; with inverter on it did not take over at all; early firmwareyoutube.com (opens in a new tab)
    • 0 ms claimedJackery US page · checked 2026-11-13"True 0ms UPS switching" headline; manual limits 0ms to Online UPS on the 120V outlets; FAQ says 20ms through the Smart Transfer Switchjackery.com (opens in a new tab)

    3 labs agree

    • 20 ms measuredGearDiary owner (Sep 2026) · checked 2026-11-13Smart Transfer Switch with UPS mode on: about 20 ms; about 1 s if charging when the grid fails; about 5 s with UPS mode off. Reviewer's figures, method not statedgeardiary.com (opens in a new tab)
    • 20 ms claimedJackery manual · checked 2026-11-13Backup UPS (default) <20ms; Online UPS 0ms but only the NEMA 5-20 outlets, max 3600W; L14-30R and 14-50 cannot be used in bypass when charging from a wall outletr.jackery.net (opens in a new tab)
    32 °Fclaimed

    Charges down to (°F)

    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall API · checked 2026-11-13CPSC API searched by RecallTitle, Manufacturer and RecallDescription = Jackery: all empty on 2026-11-13saferproducts.gov (opens in a new tab)
    134.5 lbclaimed

    Weight (lb)

    5 yearsclaimed

    Warranty (years)

    • 5 years claimedJackery manual · checked 2026-11-135 years standard; FAQ says extended warranty not supported while the series page lists a 2-year extension fee (see notes)r.jackery.net (opens in a new tab)
    JackeryHomePower 3600 PlusPower station Link
    34 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    Sources disagree

    • 21 W measuredHOBOTECH (YouTube, Sep 2025) · checked 2026-11-13inverter on 24 h with no load used 14% of battery on the display (~502Wh); display-based estimateyoutube.com (opens in a new tab)
    3,201.32 Whmeasuredsources disagree

    Usable energy, measured (Wh)

    Sources disagree

    3,584 Whclaimed

    Rated capacity (Wh)

    3,600 Wclaimed

    Continuous output (gas: running watts) (W)

    • 3,600 W claimedJackery manual · checked 2026-11-134x NEMA 5-20 (2400W each, 3600W total) plus 1x NEMA TT-30 120V 30A 3600W; 120V only from one unitr.jackery.net (opens in a new tab)
    7,200 Wclaimed

    Surge (gas: starting watts) (W)

    only with two units paralleledclaimed

    240 V output

    • only with two units paralleled claimedJackery manual · checked 2026-11-13AC Expansion Port 240V 30A 7200W (14400W surge) indicates the output during parallel operation of two units; parallel cable (Jackery Connector, its price on US page) sold separately; in parallel the units charge from solar only, AC wall charging not supportedr.jackery.net (opens in a new tab)
    not stated by the maker
    10 msclaimed

    UPS switchover (ms)

    • 10 ms claimedJackery manual · checked 2026-11-13"within 10 ms"; manual: does not support 0 ms switching, test compatibility several times, connect one device at a timer.jackery.net (opens in a new tab)
    -4 °Fclaimed

    Charges down to (°F)

    • -4 °F claimedJackery manual and US page · checked 2026-11-13charge and discharge range -4F to 113F; see conflict with product FAQ reported by BackupPowerHubr.jackery.net (opens in a new tab)
    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall API · checked 2026-11-13CPSC API searched by RecallTitle, Manufacturer and RecallDescription = Jackery: all empty on 2026-11-13saferproducts.gov (opens in a new tab)
    77.16 lbclaimed

    Weight (lb)

    5 yearsclaimed

    Warranty (years)

    • 5 years claimedJackery manual · checked 2026-11-133 years standard plus 2 years on registration; limited to original purchaser; only for purchases from Jackery, Jackery-branded third-party platforms or authorised dealersr.jackery.net (opens in a new tab)
    OUPESMega 1 LitePower station Link
    not measured
    854.94 Whmeasured

    Usable energy, measured (Wh)

    • 854.94 Wh measuredCNET Labs · checked 2026-11-1379.93% round-trip efficiency; CNET did not fridge-test medium unitscnet.com (opens in a new tab)
    1,024 Whclaimed

    Rated capacity (Wh)

    • 1,024 Wh claimedOUPES (Amazon US listing title) · checked 2026-11-13LiFePO4See our pick
    2,000 Wclaimed2 labs agree

    Continuous output (gas: running watts) (W)

    • 2,000 W claimedOUPES (Amazon US listing title) · checked 2026-11-134,500W surge in the titleSee our pick

    2 labs agree

    not measurednot measurednot stated by the maker
    <=20claimed

    UPS switchover (ms)

    • <=20 claimedOUPES (manual and US page) · checked 2026-11-13'EPS function is enabled by default'; total input and output under 2,000 W; 'do not connect ... to equipment requiring 0ms'cdn.shopify.com (opens in a new tab)
    not measured
    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13no recall row names OUPES, Mega 1 or S1 Lite (10,134 rows searched 2026-11-13)cpsc.gov (opens in a new tab)
    26.8 lbclaimedsources disagree

    Weight (lb)

    Sources disagree

    5+1claimed

    Warranty (years)

    • 5+1 claimedOUPES (US page) · checked 2026-11-13basic 5 years, plus 1 when registered; EAST KY PREPPER's warranty card says the sameoupes.com (opens in a new tab)
    PECRONE1000LFPPower station Link
    18 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    Sources disagree

    • 17 W measuredThe Solar Pit (YouTube) · checked 2026-11-13worked out: 40% of the rated 1024 Wh lost in 24 h. AC inverter on, no load, 24 h (about 17 W by our arithmetic)youtube.com (opens in a new tab)
    • 12 W claimedPECRON (manual) · checked 2026-11-13'The self-consumption of E1000 LFP is approximately 12W', used in the manual's runtime formula with 95% DoD and 93% inverter efficiencycdn.shopify.com (opens in a new tab)
    not measured
    1,024 Whclaimed

    Rated capacity (Wh)

    1,800 Wclaimed

    Continuous output (gas: running watts) (W)

    3,000 Wclaimed

    Surge (gas: starting watts) (W)

    not measured
    floating on battery; grounded when charging or in UPS modemeasured

    Neutral-ground bond

    • floating on battery; grounded when charging or in UPS mode measuredJasonoid (YouTube) · checked 2026-11-13outlet tester: open ground with inverter on battery; ground picked up when the AC charging cable is connectedyoutube.com (opens in a new tab)
    13.5 msmeasuredsources disagree

    UPS switchover (ms)

    • 13.5 ms measuredJasonoid (YouTube) · checked 2026-11-13oscilloscope on the AC output in UPS mode, desktop PC under stress test plus monitor and lights; PC stayed on in three cuts. Video 2025-03-21 (older than 12 months);youtube.com (opens in a new tab)

    Sources disagree

    • 8-20 ms claimedPECRON (manual) · checked 2026-11-13UPS protects loads under 1,800 W; 'we recommend that you only connect one device at a time'; not for loads needing under 8 mscdn.shopify.com (opens in a new tab)
    not measured
    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13no recall row names Pecron or E1000LFP (10,134 rows searched 2026-11-13)cpsc.gov (opens in a new tab)
    29 lbclaimed

    Weight (lb)

    2+1claimed

    Warranty (years)

    • 2+1 claimedJasonoid (YouTube), Soldier Knows Best · checked 2026-11-132 years plus 1 when registered within 30 days (Soldier Knows Best, https://www.youtube.com/watch?v=ZeqSa_SP7K4)youtube.com (opens in a new tab)
    PECRONF1000LFPPower station Link
    14 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    • 14 W measuredThe Solar Lab · checked 2026-11-13AC inverter on, no load; video says 'about 14 watts' (https://www.youtube.com/watch?v=aSYI5nqva3k, 2026-05-19)thesolarlab.com (opens in a new tab)

    Sources disagree

    886 Whmeasured

    Usable energy, measured (Wh)

    • 886 Wh measuredJM Pure Reviews (YouTube) · checked 2026-11-13~300 W space heater for 2 h 53 min, 88.24% of 1,004 Wh; video 2026-03-14youtube.com (opens in a new tab)
    1,004 Whclaimed

    Rated capacity (Wh)

    1,500 Wclaimed

    Continuous output (gas: running watts) (W)

    • 1,500 W claimedPECRON (manual) · checked 2026-11-13pure sine 100-120V, four AC outlets; no surge figure in the manual (JM Pure Reviews reads 3,000 W surge off the packaging)cdn.shopify.com (opens in a new tab)
    not measurednot measurednot stated by the maker
    8-20 msclaimed

    UPS switchover (ms)

    • 8-20 ms claimedPECRON (manual) · checked 2026-11-13UPS protects loads under 1,500 W; AC output restarts automatically when mains returns after the battery was depleted; not for loads needing under 8 mscdn.shopify.com (opens in a new tab)
    not measured
    none foundclaimed

    CPSC recall

    23.9 lbclaimed

    Weight (lb)

    2+3claimed

    Warranty (years)

    • 2+3 claimedJM Pure Reviews; FamilyGeekery · checked 2026-11-132 years, plus 3 when registered (FamilyGeekery: https://www.youtube.com/watch?v=T50e1i99ky0); manual: warranty void if left uncharged or unused more than six monthsyoutube.com (opens in a new tab)
    PECRONF3000LFPPower station Link
    37.81 Wmeasuredsources disagree

    Idle draw with the AC on (W)

    • 37.81 W measuredThe Solar Lab · checked 2026-11-13first review: charged to 100% and drained with only the inverter on (review text rounds to 37 W)youtube.com (opens in a new tab)

    Sources disagree

    not measured
    3,072 Whclaimed

    Rated capacity (Wh)

    3,600 Wclaimed2 labs agree

    Continuous output (gas: running watts) (W)

    2 labs agree

    4,500 Wclaimed2 labs agree

    Surge (gas: starting watts) (W)

    2 labs agree

    • 4,500 W measuredThe Solar Lab · checked 2026-11-13ran a 4,500 W load about 10 s before tripping; 4,651 W in both the first and one-year tests (video 2026-09-18)thesolarlab.com (opens in a new tab)
    120V onlyclaimed

    240 V output

    • 120V only claimedPECRON (manual) · checked 2026-11-13US manual (LV version): AC output voltage setting '100V/110V/120V (LV Version)'; 220-240 V is the HV version sold elsewhere; no 240 V split-phase outletcdn.shopify.com (opens in a new tab)
    not stated by the maker
    8-20 msclaimed

    UPS switchover (ms)

    • 8-20 ms claimedPECRON (manual) · checked 2026-11-13UPS protects loads under 1,800 W only; manual: not for loads needing under 8 ms (servers, workstations); 'not supported in some regions'cdn.shopify.com (opens in a new tab)
    32 °Fclaimed

    Charges down to (°F)

    none foundclaimed2 labs agree

    CPSC recall

    2 labs agree

    • none found claimedCPSC recall listing · checked 2026-11-13re-checked 2026-11-13 on the full listing: no row names Pecron or F3000LFP; still its price (pre-order) on Amazon US, not under $500cpsc.gov (opens in a new tab)
    63.3 lbclaimed

    Weight (lb)

    2+3claimed

    Warranty (years)

    WestinghouseiGen5000DFcGenerator Link
    n/a: runs on fueln/a: runs on fueln/a: runs on fuel
    3,900 Wclaimedsibling’s figure

    Continuous output (gas: running watts) (W)

    • 3,900 W claimed sibling’s figureWestinghouse (iGen5000DFcv manual) · checked 2026-11-13maker's manual library lists only the iGen5000DFcv manual for this family (DFcv = DFc with wheel-and-handle kit); Wirecutter quotes the same 3,900/5,000 for the DFcimages.thdstatic.com (opens in a new tab)
    5,000 Wclaimedsibling’s figure

    Surge (gas: starting watts) (W)

    • 5,000 W claimed sibling’s figureWestinghouse (iGen5000DFcv manual) · checked 2026-11-13number from the Westinghouse iGen5000DFcv manual (DFc with wheel-and-handle kit); no separate DFc manual in the maker's libraryimages.thdstatic.com (opens in a new tab)
    120 Vclaimedsibling’s figure

    240 V output

    floatingclaimedsibling’s figure

    Neutral-ground bond

    • floating claimed sibling’s figureWestinghouse (iGen5000DFcv manual) · checked 2026-11-13SIBLING manual (iGen5000DFcv, Home Depot copy): 'AC Grounding System: Neutral floating'. Every Westinghouse inverter manual kept says the same (iGen4000DFc; iGen2800DFc: https://files.bbystatic.com/5T%2FakJoNFiz5R6lludWxOw%3D%3D/8b670ff3-dfa7-4e28-b5d9-8fe1e3427cde.pdf). The DFc's own manual was not obtained: manuals.dk and notice-facile are behind bot walls (Chrome refused manuals.dk), the manuals.plus 'iGen5000DFc EFI' copy has no grounding line, westinghouse.com returned HTTP 429.images.thdstatic.com (opens in a new tab)
    n/a: runs on fueln/a: runs on fuel
    none foundclaimed

    CPSC recall

    • none found claimedCPSC recall listing · checked 2026-11-13Westinghouse (MWE Investments) generator recalls: 20-185 (WGen5300DFv, iGen4500DF fuel leak, 2020) and 18-055 (iGen2500, iPro2500 overheating, 2017); none names iGen5000DFccpsc.gov (opens in a new tab)
    not measurednot measured
    WestinghouseWGen9500DFcGenerator Link
    n/a: runs on fueln/a: runs on fueln/a: runs on fuel
    9,500 Wclaimed

    Continuous output (gas: running watts) (W)

    12,500 Wclaimed

    Surge (gas: starting watts) (W)

    120/240claimed

    240 V output

    bondedclaimed

    Neutral-ground bond

    n/a: runs on fueln/a: runs on fuel
    none foundclaimed

    CPSC recall

    not measurednot measured

    Change log

    1. First published: 20 home-backup products (15 power stations, 5 generators) by exact US variant, 12 columns, 31 conflicting figures kept beside the leading ones.

    Where each number comes from

    ColumnWhich figure leadsShown beside it
    Usable energyCNET Labs, wherever it tested, because it runs every station at the same steady loadOther labs' results
    Idle drawThe measured figureThe maker's figure, which leads only where nobody measured
    SurgeThe maker's figure, because that is the promise being checkedMeasured results
    Generator outputGasoline ratings on dual-fuel modelsPropane ratings stay on each review

    The load presets show their sources on screen too. The fridge comes from The Solar Lab's three household fridges, each measured over a full day. Motor starting allowances come from the wattage table in the Westinghouse manual, and the default outage length is EIA's 2024 national average.

    We dropped columns that would compare unlike things. Fridge runtime hours stay on each review because every lab used a different fridge, and noise readings stay off because they range from a foot away to across the yard. Results are ordered by which boxes pass your checks, then by whether they cover your outage, then by hours. Never by price, score or anyone's ranking.

    What "not measured" means

    It means we looked and found nothing on that exact model. It is never a guess, and never a figure borrowed from a predecessor or an overseas version. In a factory, a part that ships with a blank on its inspection sheet gets sent back. I would rather show you the blank than fill it with something that looks like a measurement.

    Citing the data

    How do I cite a number from this table?

    Every row has a link that never changes, built from its id, for example /home-backup-power-calculator/#jackery-explorer-5000-plus. A discontinued product keeps its row, marked. Each row has a cite action that gives the site name, the table's title, the latest change-log date and that link. The full table downloads as a CSV with every value's unit, kind, author and source. Our compilation and words are licensed CC BY 4.0; every figure stays its original source's, and the credit travels with it. The change log under the table dates every value that moves; the first entry is 2026-11-13.

    Cite this

    Download CSV

    Porchlight, Home backup power measurements, updated 2026-11-13, https://solarpowerguides.com/home-backup-power-calculator/

    Licence: CC BY 4.0 (opens in a new tab), covering only our compilation and words (the selection, arrangement, verdicts and notes). Every figure stays its source’s and is credited.

    Which page answers your situation?

    The calculator marks boxes. The buying pages make the calls:

    If you tick "gas is fine too", the generators join the list. A generator belongs outdoors, well clear of any opening into the house, and a working carbon monoxide alarm belongs inside. No machine on this page is worth a family's air.

    Every number here has a name and a date on it, and the blanks are the most honest cells in the table.

    The evidence in full

    Sources

    ↑ ↓ to move↵ to open