17 reviewsAll reviews →
Review · Power station

BLUETTI Apex 300 review for home backup: measured against the maker's claims

As an Amazon Associate I earn from qualifying purchases.

BuyUnder $1,900
Check price at BLUETTIOpens bluettipower.com · Prices change often
The verdict

Porchlight's call on the BLUETTI Apex 300 is buy, for a house that wants one battery box, wired in by an electrician, to carry its essentials and a soft-started central AC at 240 V.

  • Who it’s forA house with an electrician-installed transfer switch or subpanel, backing up essentials and a soft-started central AC
  • The catchEach 120 V leg carries only 1,920 W, so a motor without a soft start can trip it

In the evidence table

Open the full row
Idle draw with the AC on
20 Wmeasured
Usable energy, measured
2,480 Whmeasured
Rated capacity
2,764.8 Whclaimed
Continuous output (gas: running watts)
3,840 Wclaimed
Surge (gas: starting watts)
7,680 Wclaimed
240 V output
yesclaimed
Neutral-ground bond
not stated by the maker
UPS switchover
16 msmeasured

Most power stations need a second unit and a hub before they will make 240 V. The BLUETTI Apex 300 does it alone, from one outlet. Testers have fed a subpanel from it and run whole-house central air. The catch hides inside that 240 V. It is two 120 V halves, each limited to 1,920 W, and a motor that leans too hard on one half shuts the box down. Porchlight's call on the Apex 300 is buy. It is for a house that wants one battery box, wired in by an electrician, to carry its essentials and a soft-started central AC through an outage. The evidence on this exact US unit is solid: two labs and four other testers, mostly in agreement.

Check price at BLUETTIOpens bluettipower.com · Prices change often

What you get with the BLUETTI Apex 300

Price band: under $1,900

BuyPower station

Think of it as an appliance with handles. It weighs 83.78 lb (38 kg) and has no wheels; the trolley is extra. Its best trick needs wiring. Set the selector to 240 V and the NEMA 14-50 outlet feeds a transfer switch or an interlocked subpanel. The battery holds 2,764.8 Wh and takes up to six add-on packs. Reviews that quote twice that figure counted one add-on in. There are no USB ports and no car-style socket. On a box at this price, that is a new pickup with no cup holders.

BLUETTI's manual asks for a dedicated two-pole breaker upstream and a licensed electrician to confirm the circuit. Take that literally. Wired wrong, a box that pushes 240 V into your panel can push it out toward the utility line, where a lineworker could be working.

Day to day it is quiet and quick to refill: about two and a half hours from empty on the cable in the box, by three testers' clocks. For a house with an electrician lined up, we'd buy it.

Check price at BLUETTIOpens bluettipower.com · Prices change often

BLUETTI's claims, and what testers actually measured

Every row is the US unit, model APEX300. None of these testers says BLUETTI paid for the review. Most don't say where their unit came from, and one used an early test unit.

What BLUETTI promisesWhat testers gotWho measured it, and when
A 2,764.8 Wh battery2,480 Wh out at a heavy load; 2,390 Wh in a lab runThere's A Trick For That, Oct 2025; StorageReview, Nov 2026
3,840 W continuousHeld 4,300 W for about two minutes with an overload warning, then shut offThere's A Trick For That, Oct 2025
1,920 W per 120 V leg in 240 V mode (manual)A large window AC with no soft start overloaded one leg; it started fine in 120 V modeThere's A Trick For That, Oct 2025
7,680 W surge "for devices with high startup power demands" (landing page); resistive loads only (manual)No one has measured a motor start against itNot tested
About 20 W to run itself (manual)Paces of 20 W and 16 W with the AC on and nothing plugged in, measured over part of a chargeThe Solar Lab, Oct 2025; There's A Trick For That, Oct 2025
0 ms switchover in a power cut; the manual limits it to two outlets and one mode16 ms on the slower 120 V path; a desktop PC stayed on with both kinds of outletStorageReview, Nov 2026; There's A Trick For That, Oct 2025
Four fifths full in three quarters of an hour, on an optional heavy cable2.42 h, 2.49 h and 2.5 h to full on the cable in the boxCNET Labs, Aug 2026; There's A Trick For That, Oct 2025; The Solar Lab, Oct 2025
No efficiency figure66.63% round trip, wall to battery to outlet; 85% on discharge aloneCNET Labs, Aug 2026; The Solar Lab, Oct 2025
No fridge figure30.43 h on the lab's fridge; 47.6 h on one tester's kitchen fridgeCNET Labs, Aug 2026; There's A Trick For That, Oct 2025
No light-load figureA single bulb ran 35.2 h, delivering less total energy than the heavy-load runsBackyard Solar Project, early test unit, Jun 2025
6,000 cycles of battery lifeNot tested; no one has owned one long enoughNot tested

Will the Apex 300 start a well pump or an air conditioner?

Sometimes. Why it sometimes doesn't is the most important thing on this page.

The surge figure on BLUETTI's landing page, 7,680 W, is pitched at "devices with high startup power demands." The manual calls the same number Power Lifting and limits it to resistive loads: heaters and kettles, nothing with a motor. So the surge serves the loads that never needed it. In jet-engine work, a part whose drawing and spec sheet disagree doesn't ship until someone settles which is right. Here the brochure and the manual disagree, and I'd side with the manual. BLUETTI publishes no motor-start rating at all.

The deeper limit is how it makes 240 V. StorageReview's testing points to a separate inverter for each line, and the manual caps each line at 1,920 W. In 240 V mode, each 120 V outlet and circuit draws from its own half only. So a big window AC with no soft start overloaded one leg in 240 V mode. In 120 V mode, with the full 3,840 W behind it, the same unit started happily. In your house, a fridge and a window unit on the same leg fight over half the box. To its credit, it held 4,300 W for about two minutes in one test, a little over its rating.

Two real starts are on record, both feeding a subpanel at 240 V. One tester's whole-house central AC started, but only with a soft-start kit fitted, and he doesn't expect it to start without one. Another's heat pump ran fine in cooling, then its electric backup heat strip tripped the box. Those strips want more than the whole unit gives. Our page about running an air conditioner from a power station explains the soft start.

No test in our evidence puts a well pump on an Apex 300. Against pump maker Franklin's generator sizing, one Apex 300 has room for a smaller 240 V pump of three-quarter horsepower or less. From one horsepower up, it falls short without a soft start. That is arithmetic, not a test, but it is arithmetic we'd trust before a dry tap. A pump that size wants a bigger battery, and the one we back for it is the Jackery Explorer 5000 Plus, weighed against Franklin's sizing in our 240 V well pump guide. If an engine on the panel suits your house better than any battery, that guide works through the fuel route as well.

How long will it keep the fridge cold?

A day and a quarter to two days on the fridge alone, depending on the fridge. Full rundowns at heavy loads drew close to nine tenths of the labeled battery.

BLUETTI also prints a number most makers hide: about 20 W just to keep the box running. With nothing plugged in, testers measured paces of 20 W and 16 W over part of a charge. Those project to losing a sixth to a fifth of the battery each day before the fridge gets any. Picture two LED bulbs burning around the clock.

One setting can spoil food. BLUETTI's manual says ECO mode is on out of the box and cuts the AC outlets after four hours of near-zero draw. It tells you to switch ECO off for a fridge or any small load. A fridge resting overnight can be unplugged by its own battery.

The weakest number is the round trip. CNET measured 66.63%: of every three units you put in, about two come back out. Charging losses and idle draw explain much of that. It is still low against CNET's other stations, and nobody knows why. Refill it from a gas generator and that loss is fuel you pay for; our page on pairing a home battery with a generator works through it. A house with nothing on 240 V, riding out week-long outages on a 120 V generator, is better matched to the Anker SOLIX F3000. That is the battery both our fridge-runtime guide and our generator-versus-battery guide pair for that job. The home backup power calculator turns your own essentials into hours.

Will it keep a computer or CPAP running when the power goes out?

A computer, probably. A CPAP, untested. The manual promises 0 ms only on its two leftmost outlets, with the box set to 240 V and the grid on the standard input. Elsewhere it is slower; StorageReview timed 16 ms on the 120 V path. A desktop PC stayed on through a cut on both kinds of outlet. If the router and a desk riding through short, frequent cuts are all you need, a wired-in 240 V box is overkill; our guide to budget power stations names the EcoFlow DELTA 3 Classic for that job. No one has run a CPAP or oxygen machine on the Apex 300. With no DC outlet, a CPAP runs through its AC adapter. If a medical device is why you're buying, treat that 0 ms as a promise on paper, made for two outlets. When the CPAP is the whole job and no house wiring is planned, our CPAP guide points to the Anker SOLIX C1000 Gen 2, a far lighter box you can lift onto a nightstand. Where the CPAP has to share its station with the fridge, our CPAP guide turns to the Jackery HomePower 3600 Plus and our home page to the BLUETTI Elite 300.

Will it run my gas furnace?

We don't know. A furnace's control board can refuse to light without the right neutral and ground arrangement. BLUETTI doesn't say whether the Apex 300 bonds its neutral; the manual covers only grounding the chassis. Nothing we found shows a furnace igniting on this unit. If the furnace is the reason you're buying, two of our guides answer it with other machines. For a hard-wired furnace outside California, our gas furnace guide sends you to an engine instead: the Westinghouse iGen5000DFc, connected to the panel by an electrician through an inlet box and interlock. For a household set on battery, our interlock-versus-transfer-switch guide backs the bigger Jackery Explorer 5000 Plus, wired so the house neutral stays connected.

Living with it: weight, cold garages and support

With no wheels it is a two-person lift, though once wired in you won't want to move it. Keep it somewhere above freezing. The manual sets 32 °F (0 °C) as the coldest it will charge at, and mentions no battery heater. A January garage in Minnesota is the wrong home.

The software needs watching. One licensed electrician wiring his own, with an add-on battery, found the app set to the European grid frequency. He fixed it before switching over. One RV owner fared worse. Two units arrived dead with a battery-protection fault, and a later overnight shutdown ended only after a firmware update that needed Wi-Fi. That is one person's six months. We couldn't read the owner forums or Reddit, so the owner picture is thin. Help comes by ticket: The Solar Lab found the phone line is for sales, and replies take a day or two.

The CPSC's recall listing, checked 2026-11-13, shows no BLUETTI recall.

Should you buy the BLUETTI Apex 300?

Yes, for the right house. It is one of the few single boxes that puts real 240 V into a subpanel. Full rundowns show most of its battery is really there. And BLUETTI is among the few makers to print an idle figure at all. Its one real catch is the split: each leg carries 1,920 W, and the landing page's surge figure is for heaters, not motors. It suits a house whose essentials spread across both legs.

What separates its buyer is the soft start. A house that wants a single box strong enough to get a 240 V pump or a central air compressor turning without help belongs with the bigger Jackery Explorer 5000 Plus. Our home page picks it for exactly that, and our well pump guide backs it too. The Apex 300 is for the house whose compressors already have soft starts and whose pump, if it has one, is small. A household that would rather not wire anything belongs with the Jackery HomePower 3600 Plus instead. Our home page backs that plug-in box for keeping food cold and the router lit through an outage of one to three days. Weighing the Apex 300 against other modular batteries? Our page on whole-house battery backup without solar sets them side by side.

Trust its manual over its landing page. Do that, and it is the box we'd buy to wire in for 240 V backup of your essentials and a soft-started central AC.

Check price at BLUETTIOpens bluettipower.com · Prices change often

The evidence in full

Research count: 1 models weighed; 1 maker manuals among them; across this site's research, 589 sources kept in full.

Who measured what

  • CNET Labs (US site, article dated Aug 2026): round-trip efficiency 66.63%, which the lab itself called mediocre; fridge test 30.43 h; AC recharge 2.42 h, standard cable implied. CNET's method page wasn't found, so its method is inferred from its list page. How the unit was supplied isn't stated.
  • StorageReview (Nov 2026): 2,390 Wh delivered in its lab test; switchover 16 ms on a Quarch analyzer in 120 V mode, at idle and under load. The 0 ms path in 240 V mode was not captured. Its one-inverter-per-line description comes from testing, not a teardown.
  • The Solar Lab (US, Oct 2025): idle 20 W; discharge efficiency 85%, method not stated; 2.5 h to charge on the standard 120 V cable. Found running 120 V loads in 240 V mode "finicky", and found the phone line sales-only. It says it buys many of its units and receives some free; which applies here isn't stated.
  • There's A Trick For That (US, Oct 2025): idle 16 W from the fall in charge over half a day with the inverter on, a pace rather than a rundown; 2,480 Wh from a power meter at a heavy load into a charger; his kitchen fridge ran 47.6 h; 2.49 h empty to full on the standard cable, and raising the app's input setting did not raise the charging rate; held 4,300 W in 240 V mode for about two minutes before shutting off; started his two-stage central AC, with its air handler running, with a Micro-Air soft start; the window AC with no soft start overloaded one leg in 240 V mode and started in 120 V mode; briefly ran a 240 V induction burner and oven and started a gas dryer; a desktop PC stayed on with both kinds of UPS outlet. On generator pass-through, he saw it cut charging briefly to help start a compressor.
  • Backyard Solar Project (US, early test unit, Jun 2025): a single bulb ran 35.2 h to shutdown; the video's own energy caption is garbled, so we multiplied runtime by load ourselves. That run delivered less total energy than the heavy-load rundowns, consistent with idle draw taking a bigger share at light loads, which is what most home backup is. A heat pump ran in cooling with the load split across both lines; its electric heat strip tripped the unit, which needed a reset. Each solar input caps its current, so the 2,400 W solar total is hard to reach with common panels.
  • The Solar Pit (US, Jun 2025): 53 dB while charging in Turbo from a 240 V outlet; quieter in Standard; below the meter's floor in Silent.
  • Owners: Landers Electric, a licensed electrician in San Diego, installed an Apex 300 with a B300K add-on through a Reliance transfer switch to a critical-loads subpanel (Mar 2026). Beer Money Cycle Works reported six months of RV use: BLUETTI replaced the first faulty unit and offered a refund, and the second recovered after days on solar and shore power. Both are single reports.
  • Well pump sizing: the three-quarter horsepower line comes from setting the Apex 300's per-line and total output against Franklin's generator sizing by pump horsepower. It is an inference, not a measured pump start.

Where sources disagree

  • Efficiency. CNET's round trip includes charging losses and idle draw; the discharge-only figures do not. That explains part of the gap, but CNET's figure is still low against its other stations, and whether the unit, its firmware or the test setup is responsible remains open.
  • Surge. The landing page ties 7,680 W to "high startup power demands"; the manual limits it to resistive loads. No motor-surge rating is published. Open.
  • Charge speed. The fast figure needs the optional TT-30 or L14-50 cable into the P050A port; the standard cable caps charging well below Turbo. Explained.
  • Switchover. 0 ms depends on mode and outlet, per the manual. Explained.
  • Solar. BLUETTI's larger solar figures are system totals across three linked units with add-on chargers; one box takes 2,400 W through its own inputs. Explained.
  • Capacity. Popular Science quoted the battery with one B300K add-on counted in. The base unit is 2,764.8 Wh. Explained.

Kept apart

  • The European, UK and Australian Apex 300 versions use different outlets and a different switchover; no measurement on them is used here.
  • Apex 300 bundles with B300K or B500K batteries add capacity to the same unit; results from bundle installs are labeled.
  • The older AC300 and AC500 are inverter-only boxes with no built-in battery, and a single AC300 had no 240 V.
  • The Apex 200 is a new sibling and wasn't researched.

What isn't known

  • A measured motor start, locked-rotor figure or well-pump start on this unit, with or without an add-on battery.
  • Whether the neutral is bonded in 120 V mode, 240 V mode or on a transfer switch; no furnace test.
  • UL 9540 or UL 1741 listing status, which wasn't checked.
  • Generator auto-start support.
  • The warranty term: reviewers report five years, not confirmed on BLUETTI's own page in this research.
  • Owner experience at scale, since Reddit and BLUETTI's forums couldn't be read.
  • No sump pump or CPAP test.

Sources

ReviewBLUETTI Apex 300 Under $1,900 Check price at BLUETTI
↑ ↓ to move↵ to open